Request Literature
|
 |
| ATi HALF
SHAFT Systems
are used to transmit torque from FWD half-shafts, while the vehicle is
running. The 2040HSi Miniature Strain Gage Transmitter Collar clamps to
most any half-shaft and connects directly to a full strain bridge
adhered to the shaft. The split, rotating Transmitter Collar requires
only .400" of clearance around the shaft. Power is supplied to the
Transmitter Collar by a nine volt battery or by the Model 2030i
Induction Power Supply for continuous operation. The Receiver includes
a built-in speaker and a digital backlit LCD display which can be
scaled to read out in Engineering units. The unit can be powered from
12 VDC or 120 VAC. Turn-key systems are available, including shaft
gaging and calibration. |
Model
2040HSi Transmitter Collar Assembly shown
|
| FEATURES |
| Transmits
Sensor Signals via Radio Transmitter to a Stationary Receiver
|
Transmitters
available for Strain, Torque, Pressure, Voltage, Temperature...
Most Any Type of Signal
|
| No
Shaft Modifications Required
|
Clamp-on
Collar houses Transmitter(s) and Power Supply.
Contains embedded transmitting antenna
|
| Immune
to electromagnetic interference, dust, oil, moisture, etc.
|
| No
Slip Rings
|
| Remote
Shunt Calibration Available
|
| Multi-Channel
Systems Available
|
|
- Miniature
Transmitter: Available for most any type of sensor.
Many sizes available to accommodate clearance space limitations.
- Collar
Assembly: The two-piece Model 2010B Collar Assembly
provides a convenient means of attaching any of the 2040BC Series
Transmitters to a rotating shaft. A cavity in one side houses the
Transmitter(s) while the other side houses a standard nine volt battery
or induction power conversion circuitry. Connections are automatically
made from one half to the other. Models are available for dedicated
shaft sizes or to cover a range of shaft sizes.
- Induction Power Supply (optional):
The Model 2030i IPS delivers power through a stationary loop antenna to
an antenna embedded in the collar. This power transfer provides long
term, uninterrupted measurements with no batteries.
- Remote Calibration (optional):
The RC Option enables the user to actuate a positive or negative shunt
calibration from the Receiver. The shunt calibration resistor is
located on the Transmitter.
- Automatic Turn-On (optional):
Automatically applies power to the Transmitter whenever any vibration
or rotation is detected. Power to the Transmitter automatically ceases
25 minutes after vibration or rotation is no longer detected. For use
with battery-powered Transmitters.
|
|